Antmed-O.S Implant System

Features

Manufacturing Standards & Strict Quality Control
  • The Antmed O.S Implant System is manufactured under strict quality standards.
  • The production line is equipped with advanced imported precision machining equipment, achieving machining accuracy of up to 2 microns.
  • A multi-level cleanroom manufacturing environment (100,000 / 10,000 / 100 grade) ensures a highly controlled production process. The entire facility adopts pharmaceutical-grade purified water systems and strict contamination control procedures.
  • Supported by advanced physical, chemical, and biological testing laboratories, each implant undergoes rigorous quality verification procedures before delivery, ensuring consistent quality and reliable performance.
D-SLA Pure Titanium Surface Technology
  • The Antmed O.S Implant System incorporates advanced D-SLA surface technology, combining spherical abrasive blasting with dual acid-etching processes to create an optimized micro-rough implant surface.
  • A specially designed 16-step cleaning procedure ensures exceptional surface purity, effectively eliminating alumina particle residue and reducing the risk of acid contamination commonly associated with traditional implant surface treatments.
  • This advanced surface technology enhances osseointegration performance around by 20%, promoting predictable bone response and long-term implant stability.
Premium Titanium Material Selection
  • Each Antmed O.S Implant is manufactured from premium Grade 4 cold-worked titanium, providing:
  • ·Tensile strength: 900–1120 MPa
  • ·Yield strength: 800–1000 MPa
  • The high-strength titanium material provides:
  • ·Excellent mechanical stability
  • ·Superior biocompatibility
  • ·Reliable osseointegration performance
  • ·Reduced risk of ion release
  • The restorative abutments are manufactured from optimized Grade 5 titanium, achieving an ideal balance between mechanical strength, precision fit, and biological compatibility.
Variable Diameter Thread Design
  • The implant features a variable diameter thread design combined with spiral cutting grooves, enabling efficient bone cutting and smooth placement with reduced insertion resistance.
  • Additional cervical threads enhance primary stability by engaging cortical bone when sufficient stability cannot be achieved in cancellous bone, making the implant suitable for a wide range of conventional implant procedures.
Hexagonal Anti-Rotation & Morse Taper Connection
  • The implant-abutment connection combines:
  • ·Hexagonal anti-rotation structure
  • ·11° Morse taper connection
  • The six anti-rotation surfaces provide excellent rotational stability while maintaining restorative convenience.
  • The Morse taper interface effectively seals the internal implant cavity, reduces micro-movement, and optimizes force transmission by converting lateral chewing forces into axial forces, significantly enhancing abutment load-bearing capacity.
Non-Contact Packaging System
  • The Antmed O.S Implant System adopts a non-contact packaging system throughout the entire production and packaging process.
  • The implant avoids direct contact with external objects, reducing contamination risks and preventing foreign particle exposure.
  • The internal fixation design minimizes friction and vibration during storage and transportation, while the integrated quick-release design improves surgical handling efficiency.
One Implant System, Two Surgical Solutions
  • Antmed introduces the innovative “One Implant System, Two Surgical Solutions” concept.
  • The system provides two instrument options:
  • ·Stop-controlled surgical instruments
  • ·Non-stop-controlled surgical instruments
  • This flexible design adapts to different surgical preferences and allows clinicians to quickly integrate the system into existing clinical workflows without changing operating habits.
UDI Traceability System & Lifetime Quality Assurance
  • All Antmed products are equipped with UDI (Unique Device Identification) codes, implementing a complete one-product-one-code management system.
  • Through digital traceability technology, Antmed enables:
  • ·Manufacturing source tracking
  • ·Distribution process monitoring
  • ·Product lifecycle management
  • In the event of quality risks, accurate product identification and efficient recall procedures can be performed to ensure product safety and reliability.
Global Service Network & Lifetime Warranty
  • Supported by Antmed’s global manufacturing capabilities and professional service network, Antmed products and services are available in more than 130 countries and regions worldwide.
  • With a commitment to long-term product reliability, Antmed provides a lifetime warranty, delivering continuous confidence and support for dental professionals and patients worldwide.

Product Introduction

Universal tapered implant design provides a versatile solution for various clinical applications, simplifying procedures and improving placement efficiency.
Variable thread design adapts to different bone conditions, enhancing cutting performance and improving initial stability.
Multi-spiral cutting groove design improves cutting efficiency, reduces insertion resistance, and enables smoother implantation.
11°Morse taper connection combined with internal hex structure provides reliable sealing, anti-rotation performance, and stable force transmission.
Optimized cervical design increases bone contact area and supports enhanced primary stability, especially in soft bone conditions.
High-strength titanium material offers excellent mechanical performance, biocompatibility, and long-term clinical reliability.
Original precision components ensure accurate matching, reliable performance, and consistent clinical outcomes.

Technical Parameters

Implant Material Grade 4 Cold-Worked Titanium
Abutment Material Low-Gap Grade 5 Titanium
Surface Treatment D-SLA (Sandblasting + Acid Etching)
Implant Design External Cylindrical & Internal Tapered Progressive Thread Design
Connection Type Hexagonal Anti-Rotation And Morse Taper Connection
Implant Placement Method Motor-Driven / Manual Placement
Restoration Options Single Crown / Multiple Units / Bridge Restoration
Implant Insertion Torque Recommended ≤70 N·cm
Screw Tightening Torque Recommended ≤30 N·cm
Surgical Kit Compatibility Compatible with Stop-Controlled and Non-Stop-Controlled Surgical Kits
Compatibility System-Based Design with Dedicated Connection Interface (Non-Universal)
Surface Residue Residue-Free Surface
Manufacturing Environment Three-Level Clean-room System (100,000 / 10,000 / 100 Grade)
Water Quality Environment Pharmaceutical-Grade Purified Water
Packaging Method Non-Contact Packaging System